Loading...

Amflow Norge supplies a comprehensive range of calibration pots designed for the oil and gas industry. Our stainless steel calibration pots from Matek (Germany) feature stressed relieved borosilicate glass for clear visibility, radial glass sealing, and all SS 316 construction. Designed to EN 1595, the range covers volumes from 2.5 ml to 40 litres with NPT or flanged ANSI B16.5 connections. Combined level gauge and calibration pot models are also available for dual-function installations. For less demanding applications, we also supply AccuDraw PVC and polypropylene calibration cylinders from Primary Fluid Systems. The full range is suitable for capacity measurements from 160 ml/hr to 2,400 l/hr.
Premium SS 316/316L calibration pots by Matek (Germany). Borosilicate glass construction designed to EN 1595 for oil and gas, petrochemical, and offshore applications. Available from 2.5 ml to 40 L with NPT or flanged connections.
AccuDraw calibration cylinders by Primary Fluid Systems in PVC and polypropylene construction. Sizes from 100 ml to 50,000 ml. Dual graduation scale in mL and GPH. Meets ISO 6706. NSF/ANSI-61 certified (PVC). Suitable for general industrial and water treatment applications.
17 products in this category

Stainless steel calibration pot with 2.5 ml volume. Capacity scale range 0–160 ml/hr. 1/2" NPT or 1/2" 150# flanged connections.
Key Specifications

Stainless steel calibration pot with 5.5 ml volume. Capacity scale range 0–340 ml/hr. 1/2" NPT or 1/2" 150# flanged connections.
Key Specifications

Stainless steel calibration pot with 9 ml volume. Capacity scale range 0–0.55 l/hr. 1/2" NPT or 1/2" 150# flanged connections.
Key Specifications

Stainless steel calibration pot with 20 ml volume. Capacity scale range 0–1.2 l/hr. 1/2" NPT or 1/2" 150# flanged connections.
Key Specifications

Stainless steel calibration pot with 45 ml volume. Capacity scale range 0–2.7 l/hr. 1/2" NPT or 1/2" 150# flanged connections.
Key Specifications

Stainless steel calibration pot with 100 ml volume. Capacity scale range 0–6.0 l/hr. 1/2" NPT or 1/2" 150# flanged connections.
Key Specifications

Stainless steel calibration pot with 220 ml volume. Capacity scale range 0–13 l/hr. 1/2" NPT or 1/2" 150# flanged connections.
Key Specifications

Stainless steel calibration pot with 500 ml volume. Capacity scale range 0–30 l/hr. 1/2" NPT or 1/2" 150# flanged connections.
Key Specifications

Stainless steel calibration pot with 1,000 ml volume. Capacity scale range 0–60 l/hr. 3/4" NPT or 3/4" 150# flanged connections.
Key Specifications

Stainless steel calibration pot with 2,200 ml volume. Capacity scale range 0–135 l/hr. 3/4" NPT or 3/4" 150# flanged connections.
Key Specifications

Stainless steel calibration pot with 4,000 ml volume. Capacity scale range 0–240 l/hr. 1" NPT or 1" 150# flanged connections.
Key Specifications

Stainless steel calibration pot with 6.5 litre volume. Capacity scale range 0–400 l/hr. 3/4" NPT or 3/4" 150# flanged connections.
Key Specifications

Stainless steel calibration pot with 10 litre volume. Capacity scale range 0–600 l/hr. 1" NPT or 1" 150# flanged connections.
Key Specifications

Stainless steel calibration pot with 22.5 litre volume. Capacity scale range 0–1,350 l/hr. 1" NPT or 1" 150# flanged connections.
Key Specifications

Large stainless steel calibration pot with 40 litre volume. Capacity scale range 0–2,400 l/hr. 2" 150# flanged connection only.
Key Specifications

Translucent PVC calibration cylinder for accurate metering pump calibration. Available 100 mL to 50,000 mL. Four styles with NPT, BSPT, socket, or flanged connections. Dual mL/GPH scale. NSF/ANSI-61 certified.
Key Specifications

Translucent polypropylene calibration cylinder for metering pump calibration. Available 100 mL to 4,000 mL. Three styles with NPT, BSPT, socket, or flanged connections. Graduated in mL. Meets ISO 6706.
Key Specifications
Choose flow, connection, material, and seal to generate the Matek model code directly on the Calibration Pots page.
This selector uses the Matek calibration pot table from the supplied PDF. Optional code suffixes such as GPH, GPD, and R are not included in this version.
Looking for a specific product or configuration not listed here?
Contact us for custom requirementsContact our technical team for detailed specifications, pricing, and lead times for calibration pots.
Contact Us